technicial_specifications
Continuous Rating | 1560 ekW @1.0pf 1560 ekW @1.0pf |
Fuel Type | Natural Gas, Biogas, Coal Gas Natural Gas, Biogas, Coal Gas |
Maximum Electrical Efficiency | 43.30% 43.30% |
Frequency | 50 or 60 Hz 50 or 60 Hz |
RPM | 1500 or 1800 rpm 1500 or 1800 rpm |
Engine Model | CG170-16 CG170-16 |
Displacement | 4320 in³ 70.8 l |
Aspiration | TA TA |
Bore | 6.7 in 170 mm |
Stroke | 7.7 in 195 mm |
Length | 261.4 in 6640 mm |
Width | 70 in 1778 mm |
Height | 87 in 2210 mm |
Dry Weight - Genset | 32848.5 lb 14900 kg |
advantages_and_features
High Efficiency, Lower Operating Costs
- Miller cycle timing with combustion chamber and spark plug improvement help on saving up to 15% fuel gas per year
- CG170 (non-miller) is optimized for Island-Mode capability
- Gearbox helps limit wear and tear on engine components, lowering operating costs and increasing availability
Low installation, Building and Operating Costs
- Extended maintenance intervals thanks to sooth-free combustion and enlarged oil tank
- Low fuel consumption due to improved combustion chamber and pre-chamber spark-plugs
- Flexible fields of application also with fluctuating gas qualities due to Total Electronic Management (TEM)
- Optimized oil management
Optimized Lubrication Consumption
- Consumes up to 1900 liter less lube oil per year than comparable models<\li>
- Longer lubricant change and oil change intervals<\li>
standard_equipment
-
Air Inlet
- Turbocharger with a water-cooled bearing case for all cylinder
- One-element single-stage air cleaner with enclosure and sevice indicator
-
Control Panels
- TEM (Total Electronic Management)
-
Cooling
- Jacket water and SCAC thermostats
- Electrical jacket water and aftercooler coolant pump
- flange connections for JW inlet and outlet
- Cat flanges on SCAC circuit
-
Exhaust
- PEARL/Low resistence exhaust system
- Closed crankcase ventilation system
-
Fuel system
- Independently controlled cylinder monitoring and ignition system
- Pre-chamber spark plugs
- Electronic fuel metering valve
-
Generator
- Busbar connections
- Anti-condensation space heater
- closed-coupled generator result in no torque transmission to the base frame
- Winding temperature detectors
- Reactive droop
- 3-phase sensing and KVAR/PF control
- grid code generator
-
Starting/Charging
- 24V starting motors
- Battery disconnect switch
-
General
- Crankshaft vibration damper and guard
optional_equipment
-
Air Inlet
- Mounting stand
- Air cleaner with precleaner
-
Cooling
- CHP skid
-
Grid Code Compliance
- 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands