C2.2 (60 Hz)

C2.2 (60 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating 20.0 ekW 20.0 ekW
Minimum Rating 15.5 ekW 15.5 ekW
Emissions/Fuel Strategy R96/EUIIIa Equivalent R96/EUIIIa Equivalent

Technicial Specifications

Generator Set Specifications
Maximum Rating 20.0 ekW 20.0 ekW
Minimum Rating 15.5 ekW 15.5 ekW
Emissions/Fuel Strategy R96/EUIIIa Equivalent R96/EUIIIa Equivalent
Voltage 110 to 415 Volts 110 to 415 Volts
Frequency 60 Hz 60 Hz
Speed 1800 rpm 1800 rpm
Duty Cycle Standby, Prime Standby, Prime
Engine Specifications
Engine Model Cat® C2.2, In-line 4, 4-cycle diesel Cat® C2.2, In-line 4, 4-cycle diesel
Bore 3.3 in 84 mm
Stroke 3.9 in 100 mm
Displacement 135.2 in³ 2.2 l
Compression Ratio 22.5:1 22.5:1
Aspiration Naturally Aspirated Naturally Aspirated
Fuel System Indirect Injection Indirect Injection
Governor Type Mechanical Mechanical
Generator Set Dimensions
Length - Maximum 59.1 in 1500 mm
Width - Maximum 24.4 in 620 mm
Height - Maximum 43.9 in 1115 mm

Advantages and Features

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

M-Frame Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

GCCP 1.3 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
  • Image may not be a representative of actual product

Cooling System

  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

Cat Dealers provide extensive post sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Cat® SOSSM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products.

One Safe Source

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

World Wide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Standard Equipment

  • Air Inlet System
    • Air cleaner; light duty with disposable element
  • Control Panel
    • GCCP 1.3
  • Cooling System
    • Radiator and cooling fan with guards
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
    • Coolant drain line with valve
  • Exhaust System
    • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Standard open set fuel tank/base supplied
    • Base, formed steel with single wall integral 8-hour fuel tank
  • Generators and Generator Attachments
    • IP23 Protection
    • Circuit breaker, IEC, 3 pole, mounted in tower panel
    • 12 Leads
    • Segregated low voltage (AC/DC) wiring panel
    • Voltage regulator (single phase sensing)
    • Tower panel, IP22, bottom cable entry
  • Governing System
    • Mechanical governing system
  • Lube System
    • Oil drain line with valve
    • Lubricating oil
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provisions and termination points for coolant
  • Starting / Charging System
    • 12 Volt battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

  • Alternator Options
    • Coastal insulation protection
  • Certificates
    • Global certification for CIS
    • European upgrade to STD set for CE certificate
  • Circuit breakers
    • 4 Pole Circuit breaker
    • Padlockable breaker device
  • Control Panel Options
    • Volt free contacts for common alarm
    • Battery charger
    • Volt free contacts for genset running
    • Emergency stop with key
    • GCCP 1.3
  • Cooling System
    • Coolant heater
  • Enclosures
    • Single point lift for enclosure
    • Sound attenuated enclosure (GALV)
  • Fuel System
    • Skidbase for enclosures
    • Skidbase for open sets
    • 1000 Hr extended service interval
    • DEFRA bunded fuel tank
    • Fuel transfer control
    • Base feet
    • Low fuel level alarm
  • Mounting Options
    • Silencer installation kit
    • Industrial silencer removal
    • Battery removal
  • Special Test and Inspection
    • PGS Test report @ 1.0 power factor
  • General
    • Packing case - compact set
    • Radiator stone guard
    • Packing case - canopied set