C18 (60 Hz)

C18 (60 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating 600 ekW 600 ekW
Minimum Rating 455 ekW 455 ekW
Emissions/Fuel Strategy Low Fuel Consumption Low Fuel Consumption

ტექნიკური მახასიათებლები

Generator Set Specifications
Maximum Rating 600 ekW 600 ekW
Minimum Rating 455 ekW 455 ekW
Emissions/Fuel Strategy Low Fuel Consumption Low Fuel Consumption
Voltage 208 to 600 Volts 208 to 600 Volts
Frequency 60 Hz 60 Hz
Speed 1800 rpm 1800 rpm
Duty Cycle Standby, Prime Standby, Prime
Engine Specifications
Engine Model C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore 5.71 in 145 mm
Stroke 7.2 in 183 mm
Displacement 1106.4 in³ 18.1 l
Compression Ratio 14.5:1 14.5:1
Aspiration Air to Air Aftercooled Air to Air Aftercooled
Fuel System Electronic unit injection Electronic unit injection
Governor Type Adem™A4 Adem™A4
Generator Set Dimensions
Length - Maximum 218.5 in 5550 mm
Width - Maximum 80.9 in 2056 mm
Height - Maximum 107.8 in 2737 mm

უპირატესობები და მახასიათებლები

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

SR5 Alternator

A-Frame Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

EMCP Control Panel

GCCP 1.2 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

  • UL2200 Listed; CSA 22.2; Certification of Compliance – IBC Seismic; Dual IBC & HCAI

One Safe Source

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Worldwide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

სტანდარტული ტექნიკა

  • Air Inlet
    • Air cleaner
  • Air Inlet System
    • Light duty air cleaner
    • Turbocharger
    • Aftercooler core
  • Governing System
    • Cat electronic governor (ADEM A4)
  • Control System
    • GCCP 1.2
  • Cooling
    • Radiator and cooling fan with guard
    • Fan drive, battery charging alternator drive
    • Coolant drain line with valve
    • Caterpillar extended life coolant
    • Package mounted radiator
  • Exhaust
    • Exhaust flange outlet
  • Exhaust System
    • Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use - shipped loose
  • Fuel
    • Fuel priming pump
    • Secondary fuel filters
    • Primary fuel filter with integral water separator
  • Fuel System
    • Standard 8 hour open set fuel tank
  • Generator and Attachments
    • Matched to the performance and output characteristics of Cat engines
    • Integrated voltage regulator (IVR)
    • Segregated low voltage (AC/DC) wiring panel
    • A Frame generator - IP21 protection
    • Integrated voltage regulator (IVR)
    • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
    • Power center, IP22
  • Generator
    • IP23 Protection
    • Matched to the performance and output characteristics of Cat engines
    • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
  • Power Termination
    • Busbar
  • Control Panel
    • GCCP Genset Controller
  • Lube System
    • Lubricating oil
    • Oil drain valves
  • Mounting
    • Rubber vibration isolators
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator. includes lifting provisions and termination points for coolant and lube oil drain lines
  • Starting/Charging
    • 24 Volt battery with rack and cables
    • 24 volt starting motor
    • Batteries
  • General
    • Engine and alternator pre-paint, Caterpillar yellow
    • Paint - Caterpillar yellow except rails and radiators gloss black

აირჩიეთ ტექნიკა

  • Air Inlet System
    • Dual element air cleaner
    • Single element air cleaner
  • Exhaust
    • Industrial, residential, critical mufflers
  • Circuit breakers
    • 3 Pole (IEC-100% rated) Circuit breakers - Motorised
    • Power terminal strip
    • 3 Pole (IEC-100% rated) Circuit breakers - Package mounted
    • Shunt trip for IEC breaker
    • Padlockable circuit breaker device
    • Circuit breaker (IEC) Auxiliary contacts
    • 4 Pole (IEC-100% rated) Circuit breakers - Package mounted
    • 4 Pole (IEC-100% rated) Circuit breakers - Motorised
  • Generator
    • Anti-condensation heater
    • Oversize and premium generators
    • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
  • Power Termination
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
  • Control Panels
    • Load share module
    • Local & remote annunciator modules
    • GCCP 1.2, GCCP 1.5
    • Remote monitoring software
    • Digital I/O module
  • Control System
    • Protective devices: Earth fault relay - earth leageage Ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - High fuel level alarm - Fuel level sensor
    • Local alarm modules
    • Local alarm horn
    • Oil temperature displays
    • GCCP 1.5
    • Volt free contact
    • Remote annunciator module
  • Starting/Charging
    • Heavy duty starting system
    • Battery chargers
    • Jacket water heater
    • Charging alternator
    • Oversize batteries
  • Cooling System
    • Low coolant temperature alarm
    • Radiator duct flange
  • Enclosures
    • Sound attenuated enclosures
  • Exhaust System
    • Engine mounted muffler
    • 8 and 10 inch GP flanges
    • 10, 25 and 35 end in / end out mufflers
    • Manifold and turbocharger guards
    • 8 and 10 inch elbow kits
  • Fuel System
    • Manual fuel transfer pump
    • Integral - Dual wall fuel tank base
    • Fuel transfer system
  • General
    • CSA Certification
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • Integral & sub-base UL listed dual wall fuel tanks
    • Narrow, wide or skid base
    • Single or dual wall integral fuel tanks
    • Automatic transfer switches (ATS)
    • UL 2200 package
    • The following options are based on regional and product configuration:
    • Single or dual wall sub-base fuel tanks
    • EEC Declaration of Conformity
    • Sound attenuated, weather protective or high ambient weather protective enclosure
    • Enclosures: Sound attenuated, weather protective
    • EU Certificate of Conformance (CE)
  • Generator and Attachments
    • Ingress protection
    • Permanent magnet excitation (PMG)
    • A Frame CIP generator
    • LC frame generator
    • LC frame oversize generators
    • A Frame oversize generator
    • LC frame CIP generator
    • Space heaters
  • Lube System
    • Manual sump pump
  • Starting and Charging
    • Jacket water heaters
    • 5 Amp Battery charger
    • Battery disconnect switch
WhatsApp WhatsApp