Maximum Rating 600 ekW 600 ekW
Minimum Rating 600 ekW 600 ekW
Emissions/Fuel Strategy Non Regulated Non Regulated

ტექნიკური მახასიათებლები

Generator Set Specifications
Maximum Rating 600 ekW 600 ekW
Minimum Rating 600 ekW 600 ekW
Emissions/Fuel Strategy Non Regulated Non Regulated
Voltage 220 to 480 Volts 220 to 480 Volts
Frequency 60 Hz 60 Hz
Speed 1800 RPM 1800 RPM
Duty Cycle Standby Standby
Engine Specifications
Engine Model C15 In-line 6, 4-cycle diesel C15 In-line 6, 4-cycle diesel
Bore 5.4 in 137 mm
Stroke 6.8 in 171 mm
Displacement 928 in³ 15.2 l
Compression Ratio 16.1:1 16.1:1
Aspiration Turbocharged Air-to-Air Aftercooled Turbocharged Air-to-Air Aftercooled
Fuel System EUI EUI
Governor Type Adem™A4 Adem™A4
Generator Set Dimensions
Length - Maximum 131 in 3328 mm
Width - Maximum 60.6 in 1540 mm
Height - Maximum 86.1 in 2187 mm
Dry Weight - Genset (maximum) 8364 lb 3794 kg

უპირატესობები და მახასიათებლები

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

A-Frame Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

GCCP1.2 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

  • CE Certification Available
  • CIS Certification Available

One Safe Source

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Worldwide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

სტანდარტული ტექნიკა

  • Engine
    • Cat® C15 Inline 6 cylinder, 4 stroke diesel
  • Air Inlet
    • Air cleaner
  • Control Panels
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Cooling
    • Package mounted radiator
  • Alternator
    • A Frame standard alternator
  • Control Panel
    • EMCP 4 Genset controller
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Cooling System
    • Radiator and cooling fan with guards
    • Fan drive, battery charging alternator drive
  • Fuel
    • Fuel priming pump
    • Primary fuel filter with integral water separator
    • Secondary fuel filters
  • Exhaust
    • Exhaust flange outlet
  • Electrical Options
    • 3 Pole Circuit breaker
    • Neutral earth link
    • 24 Volt battery with rack and cables
  • Air inlet system
    • Air cleaner; light duty with disposable element
  • Lube system
    • Lubricating oil
    • Oil drain line with valve
  • Generator
    • Matched to the performance and output characteristics of Cat engines
    • IP23 Protection
    • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
  • Mounting system
    • Captive linear vibration isolators
    • Lifting provision and drag points
  • General
    • Engine and alternator pre paint, Caterpillar yellow
    • Engine and alternator pre paint, Caterpillar yellow
    • Paint - Caterpillar yellow except rails and radiators gloss black
  • Power Termination
    • Busbar
  • Generator and Attachments
    • Power center, IP22
    • Optional LC Frame generator - IP23 Protection
    • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
    • Integrated voltage regulator (IVR)
    • Segregated low voltage (AC/DC) wiring panel
  • Mounting
    • Rubber vibration isolators
  • Governing System
    • Cat electronic governor (ADEM A4).
  • Lube System
    • Oil drain valves
    • Oil cooler
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines
  • Starting/Charging
    • 24 volt starting motor
    • Batteries
    • 24 Volt battery with rack and cables

აირჩიეთ ტექნიკა

  • Exhaust
    • Industrial, residential, critical mufflers
  • Control panel
    • Speed and Voltage adjust potentiometers
    • PLG 4G/3G/Ethernet
    • Annunciator
    • Emergency E-Stop
  • Enclosure
    • Cat GC enclosure
  • Generator
    • Oversize and premium generators
    • Anti-condensation heater
    • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
  • Power Termination
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
  • Electrical Options
    • 4 Pole Circuit breaker
    • Auxiliary contacts
    • Padlockable circuit breaker
    • Battery charger
    • Wet battery
  • Alternator
    • Space heater
    • AVR
  • Fuel System
    • Dual wall 8 hour fuel tank
    • Single wall 8 hour fuel tank with spill containment
    • Low fuel level shutdown
    • Low and high fuel level alarms
    • Manual fuel transfer pump
    • Fuel transfer system controls
    • Dual wall fuel tank base
  • Starting/Charging
    • Jacket water heater
    • Heavy duty starting system
    • Battery chargers
    • Charging alternator
    • Oversize batteries
  • Air inlet system
    • Single stage air filter
    • Dual element air filter
  • Certifications
    • EU Certificate of Conformance (CE)
    • EAC Certification
  • Extended service coverage
    • 3, 4, 5 and 10 Years
  • General
    • The following options are based on regional and product configuration:
    • Single or dual wall integral fuel tanks
    • Narrow, wide or skid base
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • EU Certificate of Conformance (CE)
    • CSA Certification
    • EEC Declaration of Conformity
    • Integral & sub-base UL listed dual wall fuel tanks
    • UL 2200 package
    • Sound attenuated, weather protective or high ambient weather protective enclosure
    • Automatic transfer switches (ATS)
    • Single or dual wall sub-base fuel tanks
  • Enclosures
    • High ambient sound attenuated enclosures
  • Exhaust System
    • Industrial silencer
    • 10 dBA Attenuation silencer
    • Flexible exhaust fittings
    • 6 and 8 inch elbow kit
    • End in/end out mufflers - 10, 25 and 35 dBA attenuation
    • Engine mounted muffler
    • Manifold and turbocharger guards
    • 6 and 8 inch flange GP
  • Generator and Attachments
    • Oversize A Frame generator
    • Permanent magnet excitation (PMG) generator
    • Oversize LC frame generator
    • Ingress protection
    • LC frame generator
    • Space heaters
    • LC frame CIP generator
    • CIP A Frame generator
  • Lube System
    • Manual sump pump
  • Mounting System
    • Narrow skid base - replaces standard fuel tank base
  • Special Test / Reports
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
  • Starting / Charging System
    • 5 Amp single Battery charger
    • Battery disconnect switch
    • Jacket water heater
WhatsApp WhatsApp