ტექნიკური მახასიათებლები
Standby Rating | 2500 kVA 2500 kVA |
Prime Power Rating | 2275 kVA 2275 kVA |
Emissions/Fuel Strategy | Low Fuel, Low Emissions Low Fuel, Low Emissions |
Voltage | 380 to 415 Volts 380 to 415 Volts |
Frequency | 50 Hz 50 Hz |
Speed | 1500 rpm 1500 rpm |
Duty Cycle | Standby, Mission Critical, Prime, Continuous Standby, Mission Critical, Prime, Continuous |
Maximum Rating | 2500 kVA 2500 kVA |
Minimum Rating | 2000 kVA 2000 kVA |
Engine Model | 3516B TA, V-16, 4-Stroke Water-Cooled Diesel 3516B TA, V-16, 4-Stroke Water-Cooled Diesel |
Bore | 6.69 in 170 mm |
Stroke | 8.46 in 215 mm |
Displacement | 4764.73 in 78 l |
Compression Ratio | 15.5:1 15.5:1 |
Aspiration | TA TA |
Fuel System | Electronic unit injection Electronic unit injection |
Governor Type | Adem™3 Adem™3 |
Length - Maximum | 247.3 in 6282 mm |
Width - Maximum | 90 in 2286 mm |
Height - Maximum | 98.2 in 2494 mm |
Dry Weight - Genset (maximum) | 34250 lb 15535 kg |
უპირატესობები და მახასიათებლები
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
EMCP 4 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 50�C (122�F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
- EU Declaration of Conformity
- EU Declaration of Incorporation
- Eurasian Conformity
- Telecommunication Lab of China
One Safe Source
- Components used in the generator set are selected at the design stage to provide optimum package performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
სტანდარტული ტექნიკა
-
Air Inlet System
- Air cleaner; single element canister type
-
Control Panels
- 0 True RMS AC metering, 3-phase, +/-2% accuracy
- Accessory module data link
- Low oil pressure
- 1 Programmable relay outputs (Form C)
- Reverse power (kW) (32)
- Warning/shutdown with common LED indication of shutdowns for:
- Environmental sealed front face
- Programmable protective relaying functions:
- kW-hr (total)
- Auto/start/stop control
- Generator set packages include Caterpillar's voltage regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter. Limiter and exciter diode monitor
- EMCP 4.2B
- 6 Customer programmable digital inputs
- Load histogram feature
- Emergency stop pushbutton
- Reverse reactive power (kVAr) (32RV)
- Customizable screens
- Failure to start (overcrank)
- kW (per phase, average & percent)
- Low coolant level
- PLC functionality
- Communications:
- kVAr-hr (total)
- Engine cycle crank
- Coolant temperature
- kVA (per phase, average & percent)
- Controls:
- High coolant temperature
- Generator phase sequence
- Digital indication for:
- Over/under frequency (81 o/u)
- Number of I/O varies on options selected
- Low coolant temperature
- Alarm acknowledge
- 1 Programmable digital outputs
- Amps (per phase & average)
- Cat connect
- Overspeed
- Engine cool-down timer
- Operating hours
- Oil pressure (psi, kPa or bar)
- RPM
- Power factor (per phase & average)
- Serial annunciator module data link
- 24 Volt DC operation
- Overcurrent (50/51)
- Generator mounted - rear facing
- Over/under voltage (27/59)
- 3 Analog inputs
- 4 Programmable relay outputs (Form A)
- Speed adjust
- Text alarm/event descriptions
- kVAr (per phase, average & percent)
- Customer data link (Modbus RTU)
- Frequency (Hz)
- Volts (L-L & L-N)
- DC volts
- Lamp test
-
Cooling System
- Certified standard PGS provided
-
Exhaust System
- Flanged faced outlet(s)
- Dry exhaust manifold
-
Fuel System
- Fuel cooler; not included with packages without radiator
- Flexible fuel lines - shipped loose
- Secondary fuel filters
- Fuel priming pump
-
General
- Flywheel and flywheel housing - SAE No. 00
- SAE standard rotation
- Caterpillar yellow with high gloss black rails and radiator
- Right hand servicing
-
Generator and Attachments
- Low voltage:
- Busbar connections, right side extension box, bottom cable entry
- Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
- NEMA standard hole pattern
- Internal excitation (IE)
- Random wound
- Anti-condensation space heater
- Winding temperature detectors
- Form wound
- 6 Leads
- High voltage:
- Medium voltage:
- 3 Phase brushless, Salient pole
- Permanent magnet excitation (PMG)
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
- Busbar connections, top center mounted, top cable entry
-
Governing System
- ADEM A3
-
Literature
- Parts book
-
Lubrication System
- Oil drain lines and valve
- Fumes disposal
- Oil filter, filler and dipstick
- Lubricating oil
- Gear type lube oil pump
- Integral lube oil cool
-
Mounting System
- Rails - Engine/generator/radiator mounting
- Rubber anti-vibration mounts - shipped loose
- Anti-vibration mounts (shipped loose)
-
Starting System
- Battery and battery rack w/cables
- 24 Volt electric starting motor
- 45 Amp Charging alternator
- Battery disconnect switch
აირჩიეთ ტექნიკა
-
Control System
- EMCP 4.4
- Local annunciator module: [ ] NFPA 110 [ ] Custom
-
Engine Options
- Starting aids: 220V 50 Hz Jacket water heater
- Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)
- Starting motors: [ ] Standard [ ] Heavy duty
- Air cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners
- Muffler: [ ] Industrial Grade
- Battery charger: [ ] 10A [ ] 20A [ ] 35A
-
Air Inlet System
- Single element filter
- Dual element air cleaner
-
Cooling System
- Coolant
- Standard ambient ATAAC radiators
- Water level switch gauges
- Standard ambient radiators
- Optional installed ATAAC radiators
- Optional installed radiators
-
Crankcase System
- Ventilation system
- No explosion relief valves
- Explosion relief valves
-
Alternators
- Temperature rise (over 40�C ambient): [ ] 150�C [ ] 125�C [ ] 105�C [ ] 80�C
-
Power Termination
- Circuit breaker rating: [ ] 2000A [ ] 2500A [ ] 3200A [ ] 4000A
- Power Termination: Busbar, Circuit breaker
- Circuit breaker trip unit: [ ] LSI [ ] LSIG [ ] LSIG-P
-
Exhaust System
- Y Adapters
- Tier 4 clean emissions module
- Clean emission parts
- Exhaust offset
- Elbows
- Tier 4 clean emission MOD Kits
- Flexible fittings
- Tier 4 dosing cabinet
- Mufflers
- Flanges
- Flange and exhaust expanders
-
Fuel System
- Fuel priming pumps (Tier 4) - Manual or electric
- Primary fuel filter
-
Extended Service Contract (ESC)
- Extended Service Contract (ESC): [ ] 2 Year [ ] 3 Year [ ] 5 Year
-
General
- US aid emblem
- Special paint (Colors other than Caterpillar yellow or high performance paints)
-
Generators and Attachments
- Generator conversion
- Space heater
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
- Differential current transformers (DCT) 8.7 kV and 15 kV classes
- Thermostat for space heater
- Alternator air cleaner
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
-
Instrumentation
- Pyrometer and Thermocouples
-
Lubrication System
- Prelube pumps
- Lube oil in standard sump
- Oil level regulator
-
Mounting System
- IBC vibration isolators
- Puck style low efficiency isolators
- Spring type vibration isolators
-
Power Connections
- Left side power connections
- Rear power connections
- Ground cables between generator and terminal box
- 2700 Frame, four lead, four terminal
- Neutral ground connections
- Low voltage Circuit breakers
- Center post busbars
- Right side power connections
-
Special Tests / Reports
- Torsional vibration analysis reports
- PGS Test report @ 0.8 power factor
- Standard engine test charge
- Generator set fuel consumption test
- OSHPD Certification
- PGS Test report @ 1.0 power factor
- Generator test report
- Fuel consumption test
- IBC Certification
- Canadian Standards Association certification
-
Starting and Charging
- Jacket water heaters
- Electric starting motors
- Starter cover
- Air pressure regulator
- Engine barring device
- Air starting motors
- 24 Volt battery set - Dry
- 10, 20, 35 and 50 Amp Battery chargers
-
Extended Service Coverage
- Platinum, Gold and Silver coverage